Subscribe to our newsletter

Please enter your email address to subscribe
Please use WeChat to scan the QR code
REQUEST A QUOTE
Please enable JavaScript in your browser to complete this form.

Power Frequency Inverter(Pencil)

  • Rated power:2-7KW
  • Conversion time:T≤5ms
  • Inverter efficdieney:97%
  • Frequency:50Hz±0.1%
  • work environment:0-40℃

DESCRIPTION

The inverter adopts MCU microprocessor fully digital SPWM controltechnology,with pure sine wave outputUnique dynamic current loopcontrol technology.

Products characteristic:

● The inverter adopts MCU microprocessor fully digital SPWM controltechnology,with pure sine wave outputUnique dynamic current loopcontrol technology..
● Perfect protection functions for input overvoltage and undervoltage,output overvoltage and undervoltage,overtemperature,overload,and short circuit.conservation.
● Super load carrying capacity,suitable for capacitive,resistive,inductive,● High efficiency,low noise,environmental protection and energyand mixed loads.
●Strong overload capacity and impact resistance,capable of withstanding ● Automatic switching,enabling unattended operation.full load startup.
● Stable performance,safety and reliability,and ultra-long service life.
●With USB communication interface or remote communicationfunction and mobile phone short message function.

Product parameters

model

HYWS2000

HYWS3000

HYWS4000

HYWS5000

HYWS6000

HYWS7000

Rated capacity

2KW

3KW

4KW

5KW

6KW

7KW

Instantaneous power

3 times

DC input

Battery voltage

12V/24V

12V/24V/48V

24V/48V

24V/48V

48V

48V

Number of batteries

12V batter:1/2/4

Battery type

Maintenance-freelead-acid batteries

AC input

Number of phases

uniphase

Frequency

50Hz±10%

AC input

220V(165-255V)(L+N+G)

AC output

220VAC(L+N+G)±10%

charge

Floating charge voltage

DC12V:14.5V/DC24V:29V/DC48V:58V

Overcharge protection

DC12V:15.5V/DC24V:31V/DC48V:62V

Charging current

10-20Adjustable(mains mode)

MPPT

controller

Rated voltage

DC12V/DC24V/DC48V

PV input voltage

12V:16-150V;24V:24-150V;48V:60-150V

Charging voltage

DC12V:14.2V;DC24V:28.4V;DC48V:56.8V

Maximum charging current

30-60A

Solar panel power

12V:360/720W;24V:720W/1440W;48V:1440/2880W

Protection function

short circuit,reverse connection

Overcharge,over discharge,overload,low voltage

Inverter output

Inverter output

220VAC (L+N+G)±3%

Frequency

50Hz±0.1%

Conversion time

T≤5ms

Waveform distortion rate

≤3(Linear load)

dynamic response

5%(0%~100%(load)

(CF)Peak coefficient

3:01

Inyerter efficiency

97%

interface

LCD liquid crystal display

call the police

Buzzer alarm and LCD flashing alarm

Protection function

 AC input overvoltage and undervoltage;DC input overvoltage and undervoltage;Overload and overtemperature of load;Output short circuit

Overload capacity

Overload>100-120%,hold the emergency beep for 60 seconds (load shedding automatically returns to normal),and then shut down the machine; Instantaneous shutdown when overload>150%

Communication method

USB/Remote monitoring(optional)

Protection level

IP21

Anti surge capability

10/700US,5KVA;8/20US,20KA

noise

≤45db

Cooling method

Forced air cooling by fan

work environment

0-40℃

FAQs

  • How does an alkaline electrolytic bath function

    As a mature electrolysis technology, alkaline water electrolysis (AWE) plays a dominant role. The diaphragm of an electrolytic bath for alkaline water electrolysis to produce hydrogen is mainly composed of polymer materials, for the purpose of separating out gases. Both the anode and cathode are made of metal alloys, such as Ni-Mo. Water molecules are decomposed into H+ and OH- at the anode, and then H+ becomes hydrogen atoms afterwards with electrons, and further becomes hydrogen molecules (H2). OH-, under the effect of electric field between the anode and cathode, passes through the porous diaphragm to reach the anode, and then it produces one water molecule and one oxygen molecule after losing the electrons. The electrolytic bath is the core of the alkaline electrolysis device. A transformer and rectifier cabinet are needed in front of the bath to convert HV AC power into the DC power necessary for the electrolytic bath, so that electrolysis of water can be performed in the electrolytic bath.
  • Are there transparent modules from ABC?

    Because of the issue of light leakage in the gaps between he solar cells in double-glass modules, ABC generally uses glazed semi-tempered glass for the backside panel of the double-glass module, with a glazed layer formed into grids where the cells are placed. Because the requirement for accuracy and shading of the glazed layer on the back panel of the cell should be reduced, a certain amount of light leakage is allowed in the industry, without any effect on the quality and energy yield of the product. The inconsistency in light transmittance on the back panel of the single-glass module is caused by differences in light transmittance caused by variations in each model of the back panel of the module. However, when the quality of the back panel meets the certification criteria, there will be no effect on energy yield. Agents will preferentially load the same batch of modules and ship them to the downstream customers.
  • How does one operate and maintain ABC PARK?

    You can check out its operation status and make timely alarms on the mobile app. There's no need for scheduled duty shifts. It requires minimal O&M except for periodic cleaning because the equipment and materials used are made by top-tier, reliable companies.
  • How long is the service life of ABC BRIGHT products?

    The service life is 30 years, with lifetime power degradation not below 85%.

REQUEST A QUOTE

Please enable JavaScript in your browser to complete this form.
Need more information? Contact us today.
Or call us at: +86-132 8702 8881