+86-13287028881
-
joymeetrade@gmail.com
Power Frequency Inverter(GSYT Tower-type)
DESCRIPTION
The inverter has a built-in mppt solar charging controller, built-in lightning protection kit and temperature protection, so it has strong security, can operate in different modes, strong compatibility, and a wide range of application fields.

Products characteristic:
● The inverter adopts MCU microprocessor fully digital SPWM controltechnology,with pure sine wave outputUnique dynamic current loopcontrol technology.
● Super load carrying capacity,suitable for capacitive,resistive,inductive,and mixed loads.
● Strong overload capacity and impact resistance,capable of withstandingfull load startup
● Perfect protection functions for input overvoltage and undervoltage,output overvoltage and undervoltage,over temperature,overload,andshort circuit
● High efficiency,low noise,environmental protection and energyconservation.
● Automatic switching,enabling unattended operation.
● Stable performance,safety and reliability,and ultra-long service life.
●With USB communication interface or remote communication function and mobile phone short message function.
Product parameters
model |
HYGSYT1K |
HYGSYT2K |
HYGSYT3K |
HYGSYT5K |
HYGSYT7K |
|
power |
1KW |
2KW |
3KW |
4KW |
5KW |
|
Instantaneous power |
3 times |
|||||
DC input |
Battery voltage |
12V/24V/48VV |
||||
Number of batteries |
12V batter:1/2/4 |
|||||
Battery type |
Maintenance-freelead-acid batteries |
|||||
交流输入AC input |
Number of phases |
uniphase |
||||
Frequency |
50Hz±10% |
|||||
AC input |
220V(165-255V)(L+N+G) |
|||||
AC output |
220VAC(L+N+G)±10% |
|||||
充电charge |
Floating charge voltage |
DC12V:14.5V/DC24V:29V/DC48V:58V |
||||
Overimpulse voltage protection |
DC12V:15.5V/DC24V:31V/DC48V:62V |
|||||
Charging current |
10-20A Adjustable (mains mode) |
|||||
P |
Rated voltage |
DC12V/DC24V/DC48V |
||||
W |
PV input voltage |
12V:35V;24V:50V;48V:100V |
||||
M |
Charging voltage |
DC12V:14.2V;DC24V:28.4V;DC48V:56.8V |
||||
controller |
Maximum charging current |
30-60A |
||||
Protection function |
Overcharge,over discharge,overload,low voltage,short circuit,reverse connection |
|||||
Inverter output |
Inverter output |
220VAC(L+N+G)±3% |
||||
Frequency |
50Hz±0.1% |
|||||
Conversion time |
T≤5ms |
|||||
Waveform distortion rate |
≤3%(Linear load) |
|||||
dynamic response |
5%(0%~100%)(load) |
|||||
(CF)Peak coefficient |
3:01 |
|||||
Inverter efficiency |
97% |
|||||
interface |
LCD liquid crystal display |
|||||
call the police |
Buzzer alarm and LCD flashing alarm |
|||||
Protection function |
AC input overvoltage and undervoltage;DC input overvoltage and undervoltage;Overload and overtemperature of load; Output short circuit |
|||||
Overload capacity |
Overload>100-120%,hold the emergency beep for 60 seconds,(load shedding automatically returns to normal),and then shut down the machine;Instantaneous shutdown when overload>150% |
|||||
Communication method |
USB/Remote monitoring(optional) |
|||||
Protection level |
IP21 |
|||||
Anti surge capability |
10/700US,5KVA;8/20US,20KA |
|||||
noise |
≤45db |
|||||
Cooling method |
Forced air cooling by fan |
|||||
work environment |
0-40℃ |